√ 2 capacitive sensor detection channels
√ the edge of digital level output can be configured
√ LED result indication
√ capactance detection range:0~2.5nf
√ accuracy of the capacitive :10fF
√ microsecond ultrafast response speed
√ using active shielding technology to improve dectection reliability
√ adaptive low frequency excitation circuit for ultra-low EMI radiation

|
Description
|
|
| Host |
PC PLC MCU
|
| Development environment |
VC C# Labview VB Linux Python
|
| Supply voltage |
DC9-24V
|
| Output trigger |
Digital level
|
| Capacitance detection accuracy |
10fF
|
| Capacitance detection range |
0-2.5nf
|
| Response speed |
Few microsecond
|
| Detection channel |
2
|
| Temperature range |
-20℃~80℃
|
| Durability |
Over 20,000 hours
|
| Interface |
Description
|
| J1 |
VCC: Dc power supply,9-24V GND:Ground |
| J2 |
CANH:CAN Bus high line
CANL:CAN Bus low line TR:5V Trigger signal output, can be configured high and low level trigger |
| J3 | Capacitance channel 2 interface |
| J4 |
Capacitance channel 1 interface
|
|
Description
|
|
| Protocol |
CANopen DS301/DS402
|
| Baud rate |
5K-1Mbps
|


| Model |
Description
|
| Single-end mode 1 |
This mode selects the detection channel 1 work
|
| Single-end mode 2 |
This mode selects the detection channel 2 work
![]() |
| Single-end mode 3 |
It is suitable for the reagent bottle or the liquid to be tested
|
| The differential mode |
This mode is non-contact measurement mode when the coupling capacitance of the equipment frame is very large
![]() |
| CAD |
.DWG
|
| 3D file |
.STP
|
| The user manual | |
| Debug software | |
| Development of the document | |
| Certificate |
| Function |
Description
|
| Capacitance calibration |
Digital signal processing technology is used to control the measurement loop, which can improve the system reference capacitance detection significantly
|
| Optimize the algorithm to ensure the linearity of measurement |
![]() |
| Visual debugging interface |
|